Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

MPPT Solar Charge Controller

PC1600F Series MPPT Solar Charge Controller (45-80A)

MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a solar array. Each Charge Controller allows customized battery recharging.

Contact
LCD/LED Display Information

LCD/LED Display Information

Figure 1 Top Panel

1. MENU: Enter or exit setting mode
2. INC: Increase the setting data
3. DEC: Decrease the setting data
4. ENTER: Confirm the selection in setting mode

LED indicatorSystem status
5. PVGreenOnPV voltage normal
Flashing every 1sPV fault is recovering
Flashing every 2sPV fault can’t recover
OffPV is off
6. BATTYellowOnBattery voltage normal
Flashing every 1sBattery fault is recovering
Flashing every 2sBattery fault can’t recover
OffBattery is off
7. FAULTRedFlashingFault
OffNormal

8. LCD display

LCD/LED Display Information

Figure 2 Top Panel

1. LO+: The load positive terminal
2. BA+: The battery positive terminal
3. BA-: The battery negative terminal
4. LO-: The load negative terminal
5. PV-: PV array negative terminal
6. PV+: PV array positive terminal
7. REM: Communication network terminal
8. BTS: Remote external temperature terminal

LCD/LED Display Information
Solar System Connection

Solar System Connection

  • 45A/60A/80A MPPT solar charge controller(Fan cooling)
  • 12V/24V/36V/48V auto work
  • MPPT efficiency>99%,Peak conversion efficiency >98%
  • DSP processors technology ensure high speed and performance
  • Multi-stage charging mode
  • Protection: PV array short circuit, PV reverse polarity, Battery reverse polarity, Over charging, Output short circuit

Specification

ModelPC16-4515FPC16-6015FPC16-8015F
Default Battery System Voltage12V/24V/36V/48VDC (Auto detection)
CONTROLLER INPUT
PV Open Circuit Voltage100VDC@12V/ 145VDC @24V/ 145VDC @36V/ 145VDC @48V
PV Array MPPT Voltage Range16VDC~100VDC / 32VDC~130VDC / 48VDC~130VDC / 64VDC~130VDC
Max PV Input Power(12V)600W800W1050W
Max PV Input Power(24V)1200W1600W2100W
Max PV Input Power(36V)1800W2400W3150W
Max PV Input Power(48V)2400W3200W4200W
BATTERY
Absorption Voltage12.5VDC/25.0VDC/37.5VDC/50.0VDC
Refloat Voltage13.7VDC/27.4VDC/41.1VDC/54.8VDC
Float Voltage14.3VDC/28.6VDC/42.9VDC/57.2VDC
Low Voltage Protection Point10VDC/20VDC/30VDC/40VDC
Temperature Compensation coefficient-3mv/°C /cell (25°C  vef)
PATTERY
Peak Conversion efficiency98% (MPPT Efficiency 99%)
Max Charging Current45 amps continuous @ 40°C ambient60 amps continuous @ 40°C ambient80 amps continuous @ 40°C ambient
GENERAL SPECIFICATION
Radiating modeFan cooling
DISPLAY & PROTECTION
LED indicationSystematic operation, LV indication, LV protection, over charge protection, short circuit protection
LCD displayCharge voltage, charge current, voltage of storage battery, capacity of storage battery, output current
Alarm ProtectionsPV array short circuit, PV reverse polarity;Battery reverse polarity, Over charging protection;Output short circuit protection;Low voltage protection for storage battery.
MECHANICAL SPECIFICATIONS
MountingWall mount
W*H* D(mm)/Net Weight(kg)167.6*257.1*82.9mm/3kg
OTHER
Environmental RatingIndoor
Operation Temperature Range-25~55°C
Ambient humidity0~90% relative humidity(non-condensing)
Altitude≤3000m
Loading(20GP/40GP/40HQ)3000pcs  /  6000pcs  /  7200pcs
  • Brochure: PC1600F.pdf Download
  • User Manual: 420-00145-06-PC1600F.pdf Download
  • Certificates: PC1600-45A60A-ES140528264E-EMC-CE.pdf Download
  • Certificates: PC1600-45A60A-ES140528264S-LVD-CE.pdf Download
  • Certificates: PC1600-LVD-TEST-REPORT-EN62109-1-ES140528264S.pdf Download